Bagaimana cara menentukan apakah meja las 3D memerlukan kalibrasi?

Jan 02, 2026 Tinggalkan pesan

I. Verifikasi Akurasi Dasar

1. Repeatability Test: Measure 20 times consecutively using a standard part. The repeatability accuracy should be ≤0.8μm (≤0.3μm for high-precision models). If the standard deviation is >1,2μm, diperlukan kalibrasi.

2. Systematic Error Detection: Measure standard parts of different sizes (e.g., 10mm, 50mm, 100mm). If the deviation is consistently >±2,5μm, diperlukan kompensasi.

3. Verifikasi Akurasi Geometris:
Guide rail straightness: Error per meter >2μm
Worktable flatness: Full stroke error >3μm
Three-axis perpendicularity: Angular error >5 detik busur.

II. Evaluasi Sistem Penyelidikan

Calibration ball diameter consistency: If the measurement difference in different directions by the same probe is >0.8μm or the roundness error is >0,5μm, diperlukan kalibrasi ulang.

Multi-probe consistency: If the deviation of each probe measuring the same dimension is >2μm, hubungan probe memerlukan kalibrasi.

AKU AKU AKU. Inspeksi Suhu dan Perawatan

Stabilitas Suhu: Perubahan suhu sekitar > ±0,5 derajat dapat mempengaruhi akurasi.

Perawatan Harian: Bersihkan secara teratur dan periksa lubang posisi dari keausan (seperti peningkatan ukuran atau deformasi); perbaikan atau penggantian diperlukan dalam kasus yang parah.

How to determine if a welding machine is leaking electricity?